The PS-18/300 is a compact and very powerful 300 watt regulated 18V DC power supply to connect up to 16 PowerView® DC motors. The input range will automatically adjust between 90 – 250 VAC. The output has over current, over voltage, short circuit and over voltage protection. The removable front lid allows for easy access to the four connection terminals. The power supply is delivered with a wall mounting template and 4 terminal connection blocks.

Features

  • Compact and modern design with removable front lid for easy cable connections access
  • Up to 4 groups of maximum 4 motors per group can be connected via plug in terminal blocks
  • Over Current, Over Voltage, Short Circuit and Over Temperature protection
  • Plug & play installation with handy tie-wrap cable management
  • Specifically designed to provide power to maximum 16 PowerView® 18VDC motors

Dimensions

Cable Connection

Technical data

Rated input voltage (VAC)

100-240

Rated input Frequency (Hz)

47-63

Rated output voltage (VDC)

18 ± 5%

Efficiency level

> 90% at full load

No load power (W)

< 6

Max. total current output (A)

16

Max. group current output (A)

4.0

Max. power output (W)

288

Output protection (per group)

fuse T6.3A/250V

Output holdup time (ms)

8.3

Operation temp. (°C)

-40…+50

Operation humidity (%)

20…85

Storage temp. (°C)

-40…+80

Storage humidity (%)

10…95

Operational lifetime (hrs)

> 100,000 @ 25°C

Material

Plastic ABS

Colour

white

Dimensions (l x w x h, mm)

223 x 195 x 51

Weight (kg)

0.98

Approvals

CE

Logistics

Article number

17.0344.0000

Min. order qty

1 pc

Scope of delivery

PS-18/300 power supply

8P plug in type terminal block (4pcs)

Mounting template A4 sheet

Required accessory

Power cable 1m EU (17.0359.0000) or

Power cable 1m UK (17.0360.0000)

Application

PowerView® 18VDC motors

max. 16 motors

Accessories

Description

Product code

Packing Unit

Figure

Power cable 1m EU

17.0359.0000

1 pc

Power cable 1m UK

17.0360.0000

1 pc

Female jack adapter

17.0361.0000

1 pc

Safety instructions

The power supply may only installed by qualified personnel who:

  • have read and understood the mounting instructions of the power supply
  • are familiar with the electronic safety aspects
  • recognize and avoid danger which can be produced from the mechanical or electrical components
  • always observe and are familiar with the local safety, labour regulations and laws
warning drop
Never drop the motor!
warning drop
Do not immerse into liquid!
warning cut
Do not cut any cables!
warning sunlight
Avoid direct sunlight!

Important notice

Hunter Douglas Europe B.V. and its affiliates (Hunter Douglas) reserve the right to make corrections, enhancements, improvements and other changes to its products and services, and to discontinue any product or service. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products (also referred to herein as "components") are sold subject to Hunter Douglas’ terms and conditions of sale supplied at the time of order acknowledgment. Hunter Douglas warrants performance of its components to the specifications applicable at the time of sale, in accordance with its standard warranty terms. Testing and other quality control techniques are used to the extent Hunter Douglas deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. Hunter Douglas assumes no liability for applications assistance or the design of Buyers' products. Buyers are responsible for their products, applications and interfaces using Hunter Douglas components. To minimize the risks associated with Buyers' products and applications, Buyers should provide adequate design and operating safeguards. Hunter Douglas does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which Hunter Douglas components or services are used. Information published by Hunter Douglas regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Hunter Douglas under the patents or other intellectual property of Hunter Douglas. Reproduction of Hunter Douglas information in Hunter Douglas data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Hunter Douglas is not responsible or liable for any altered documentation. Information of third parties may be subject to additional restrictions. Resale of Hunter Douglas components or services with statements different from or beyond the parameters stated by Hunter Douglas for that component or service voids all express and any implied warranties for the associated Hunter Douglas component or service and is an unfair and deceptive business practice. Hunter Douglas is not responsible or liable for any such statements. Buyers acknowledge and agree that they are solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of Hunter Douglas components in its applications, notwithstanding any applications-related information or support that may be provided by Hunter Douglas. Buyers represent and agree that they have all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyers fully indemnify Hunter Douglas and its representatives against any damages arising out of the use of any Hunter Douglas components in safety-critical applications.